Ultrasonic output current calculation method and formula effective current *1.414 * effective voltage *1.414 = peak power 1. The current measured by a current measuring instrument such as a conventional ammeter is an effective value. Industrial AC voltmeter measurements are all RMS values 3. The ultrasonic output power is the peak power, and the active power of the unconventional electrical appliance is 4. U (effective) = U (peak) ultrasonic cleaning machine with root number 2 (1.414) (for the formula, please refer to the AC peak voltage related data) 5. Root number 2 (1.414) I (valid) = I (peak) The equation for the alternating current of the current peak calculation formula is: i(t)=isin(ωt)W=∫R*i(t)*i(t)dt=i*i*R*[t/2-sin(2ωt ) / (4ω)] where the upper limit of the integral is t, and the lower limit of the integral is 0. W = I * I * R * ti * i * R * [t / 2 - sin (2ωt) / (4ω)] = I * I * R*t is obtained: I*I=i*i/2-i*i*sin(2ωt)/(4ωt) When t tends to infinity, I*I=i*i/2 is obtained: I=i/2 Square root (i is the maximum value of the current, I is the effective value of the current).