Ultrasonic Cleaner with Filtering System

Oct 08, 2018

Leave a message

Basic Info


Model NO.:SB-1800DT


Cleaning Media: Wet Cleaning


Cleaning Precision: Ultra-Precision Industrial Cleaning


Principle: Physical Cleaning


Condition: New


Feature: Clean Thoroughly


Ultrasonic Power: 1800W


Trademark: SCIENTZ


Origin: China


Application: Metal Parts Cleaning


Automation: Semi-automatic


Control: Artificial


Certification: CE


Customized: Customized


Material: Stainless Steel


Frequency: 40kHz


Specification: CE


HS Code: 84863039


Product Description


Quick Detail:


1.Digital display ultrasonic cleaning time

2.Real-time display of the actual temperature in the cleaning tank

3.1-99min total working time setting

4.The operating program of the instrument uses the microcontroller software.

5.Working parameter power-off memory function

6.Equipped with a special stainless steel basket and sound reduction cover

7.The inner casing and sound reduction cover of the instrument are made of high quality stainless steel.

8.Working time countdown display

9.Room temperature -80 ° C temperature setting range

10. Frequency: 28KHz/ 40KHz (or As request)

11. With CE certification

12. OEM 

 


Applications:


1. Ultrasonic cleaning of the filter element


We know that no matter what kind of filter or filter of any kind, after a period of use, the permeability will be reduced due to impurities, and the average filter price is lower, but for the chemical fiber industry, Only imported filter, the price is nearly 10,000 yuan, and the real thing is abandoned.


Unfortunately, the ultrasonic filter cleaning machine we developed in cooperation with other scientific research units uses a concentrating ultrasonic cleaning machine, which can concentrate more than 1KW of energy on the radiation surface of 200×20mm2. The ultrasonic intensity is large and the plug can be quickly removed. At the same time, the equipment uses anti-filter device, as long as you provide the core, we can provide you with a complete cleaning device. (The equipment takes 10-15 minutes to wash a filter element). Applicable to PP cotton filter, activated carbon filter, hollow fiber filter ceramic membrane filter.


2. Ultrasonic cleaning of metal


It is well known that after the metal bar is extruded into a wire, the outer part of the wire often has a layer of carbonized film and oil. It is difficult to remove the dirt (especially the whole wire) by acid cleaning or other cleaning methods. The ultrasonic wire washing machine is According to the actual production needs, a continuous wire-cutting and high-efficiency cleaning equipment is used. The rough washing part is composed of a cleaning liquid storage tank, a transducer, a circulation pump, a filter and a matching piping system. After the wire is ultrasonically washed and washed, And then blow dry to complete the entire cleaning process. The whole set of equipment integrated control is simple, convenient and effective. It is widely used in other wires such as silk, tungsten wire, molybdenum wire, silk wire and copper wire (before insulation coating).


3. Application of ultrasonic cleaning technology in phosphating


The pre-spraying process of the product is very important. The general traditional process uses acid to treat the workpiece, which is harmful to the environment and the working environment is poor. At the same time, the big drawback of Zui is that the residual acid of the complex parts is pickled and rusted. Difficult to rinse. After the workpiece is sprayed, the time is not long, and rusting occurs along the crack, which damages the surface of the coating and seriously affects the appearance and internal quality of the product. Ultrasonic cleaning technology is applied to the pre-painting treatment, which not only can quickly peel off the dirt on the surface and the gap of the object, but also the coating layer of the coating is firm and does not return to rust.


Common problems with ultrasonic cleaner generators are:


(1) The ultrasonic cleaner turns on the power switch, and the indicator light does not light. In this case, you must check whether the power switch is intact and the leakage switch is closed. If the switch is intact and then check if the fuse is overloaded, it can basically be solved.


(2) After the ultrasonic cleaner turns on the power switch, the indicator light is on, but there is no ultrasonic output. This situation is more complicated. When repairing, first check if the connection plug of the transducer and the ultrasonic power board is loose, and then check if the fuse is blown. If everything is normal, it may be an internal fault of the ultrasonic power generator. Use a multimeter to open the power line and the fire line is open. Check if the ultrasonic transducer is burnt out after the generator failure is removed and it needs to be replaced.


(3) The DC fuse of the ultrasonic cleaner is blown. It may be that the rectifier bridge or power tube is burnt, or the transducer is aging and the current is unstable, which may cause the power generator to malfuncti


PHOTO SHOW

SB-1200DT-series-baku-Ultrasonic-Cleaner.jpg

Packaging diagram

photobank(210).jpg

Send Inquiry