Automated Microbiology Glowth Curve Analysis Stystem
Description
Technical Parameters
The fully automatic microbial growth curve analyzer is a fully automated instrument that understands the growth of microorganisms by measuring the turbidity of the sample. This product can be used in the research of microbial strains, optimization of culture conditions, and high-throughput screening and evaluation of drugs. All microorganisms (bacteria, fungi, yeasts, cells and algae) multiply in the culture medium and produce turbidity. Any turbidity and color change in the traditional test tube test can be done with the "micro test tube" in the honeycomb panel. The fully automatic growth curve analyzer can make work more efficient and can save a lot of medium and consumables (Petri dishes, test tubes, etc.). The long-term culture of microorganisms is realized by high-precision temperature control and high-speed shaking of the microplate, and the multi-strain culture of aerobic bacteria and anaerobic bacteria can be realized by gas circuit control. Analysis, the use of advanced denoising algorithms can provide more accurate microbial growth curves.
Two working modes are available: incubation mode and absorbance test mode:
1. Cultivation mode: Provide the environment required for the growth of microorganisms, and at the same time, the absorbance of the sample is regularly detected and recorded at the specified wavelength.
2. Absorbance test mode: The full spectrum absorbance test can be performed on the specified sample, and the absorbance values of different wavelengths can be given.
The system is mainly composed of three parts, namely microbial growth curve analyzer, computer PC, and mobile APP (expansion function).
The equipment is mainly composed of six subsystems: optical detection system, temperature control system, vibration control system, pneumatic control system, embedded system and host computer system.
configuration list
1. One MGC-200 host ;
2. 1 hot cover for 96 -well plate;
3. 50 96 culture plates;
4. 1 power cord;
5. 1 data cable;
6 .1 manual;
7 .1 copy of the warranty card;
8 .PC software (electronic version) 1 copy;
9. 1 air transport safe;
Performance parameters
function type |
specific function |
specific requirements |
Dimensions |
510×655×350(W * D * H) |
|
Performance |
Detection wavelength |
300-850 nm |
Minimum resolution |
1nm |
|
Absorbance range |
Maximum value 5.0 OD |
|
Linearity error |
<2% |
|
light source |
Xenon lamp |
|
Light source life |
1 billion times |
|
sampling interval |
5 -360 minutes can be set |
|
work time |
1 ~ 1600h |
|
Microplate Type |
9 6 -well plate, 4 8 -well plate, 2 4 -well plate, 1 2 -well plate |
|
Maximum number of boards |
2 pieces |
|
Maximum culture volume |
96-well plate 0.2ml; 4 8 -well plate 1.0ml; 2 4 -well plate 2.0ml; 1 2 -well plate 4.0ml ; |
|
culture temperature |
15~ 60 °C (at room temperature 25°C) |
|
Temperature control accuracy |
± 0.1 degrees |
|
heating rate |
2.5 degrees/min |
|
Shaking method |
circular shaking |
|
Vibration amplitude |
3mm |
|
Shaking speed |
200-1250rpm |
|
Hot cover to prevent condensation |
YES |
|
Multi-wavelength detection |
YES |
|
Single hole multi-point detection |
YES |
|
Reference channel selectable |
YES |
|
Sterilization module |
YES |
|
Withholding dark current function |
YES |
|
Midway temperature change function |
YES |
|
CO2 concentration detection |
/ |
|
O2 concentration detection |
/ |
|
humidity monitoring |
YES |
|
Hot Lid Type Identification |
YES |
|
Optical path normalization |
YES |
|
Air supply abnormal prompt |
/ |
|
Ease of use |
Quick Change of Orifice Plates |
Quick plate change without tools |
Troubleshooting |
The alarm code is detailed and can be quickly determined as the cause of the failure |
|
interface operation |
User-friendly interface, users can get started quickly, with fast running function |
|
Other software functions |
communication |
WIFI ( reserved extended function) |
Main interface |
Parameter setting interface, status display interface, sample selection interface, data display interface, and result analysis interface. |
|
more menu |
Startup interface, login interface, initialization interface and debugging interface |
|
Alarm function |
Equipment operation failure alarm |
Performance characteristics
* 1. Using xenon lamp as the light source, high energy, no need to preheat, high resolution, high sensitivity, fast detection, at the same time, the light source has good stability and long life, and does not need to be replaced frequently;
* 2. Using high - performance optical absorption detection system, it can perform absorbance detection on any wavelength band within the wavelength range of 300-850nm, providing solutions for quantitative detection of various biomass. Full spectrum scanning can be achieved, and the optimal wavelength suitable for the sample to be tested can be automatically analyzed;
* 3. The single-hole multi-point detection technology can be selected, and the data error caused by the single-point detection is eliminated by the algorithm, and the data results are more accurate;
4. The maximum shaking speed can reach 1250rpm, so that the liquid in a small volume can be fully mixed, and the shaking culture of microorganisms in 96, 48 , 24 , and 12 -well culture plates can be realized;
5. With standard preset program, simple operation and convenient data processing. At the same time, it supports customer-defined templates for personalized operation settings and data analysis;
*6 .It has a hot cover anti-condensation design, with cooling and heating modules, and the temperature control range is 15-60°C at room temperature. The temperature can be changed during the microbial culture to facilitate the accumulation of specific metabolites;
7. It is convenient to replace the orifice plate quickly without tools;
8. With the function of fault diagnosis, the alarm code can quickly find out the cause of the fault in time;
9. Controlled by PC software, the interface is friendly and intuitive, users can get started quickly, and it has the function of quick operation. The software displays parameter setting interface, status display interface, sample selection interface, data display interface, result analysis interface, etc.;
10. Reserved communication WIFI expansion function;
Hot Tags: automated microbiology glowth curve analysis stystem, China, factory, suppliers, wholesale, customized, buy, cheap, bulk, price list, for sale
Next