Thermostatic Digital Shaking Water Bath

Thermostatic Digital Shaking Water Bath

Water Bath Shaker, Shaking Water Bath, Digital Water Bath Shaker manufacturer / supplier in China, offering Shz-88 Thermostatic Digital Shaking Water Bath, Mk200-4 Laboratory Digital Dry Block Heater/Heating Block, HH-SC Super Thermostatic Water/Oil Bath and so on.


   This series of thermostats adopts digital intelligent constant temperature PID algorithm, which is accurate and fast in temperature control. It is the best product to replace analog temperature control. It is also a common temperature control equipment necessary for medical equipment and laboratory instruments, and is widely used in petroleum and national defense. Research departments such as metallurgy, chemical engineering, bioengineering, medical and health, life sciences, electronic instruments, factory experiments, universities, scientific research institutions, etc.

Features:

 Using enviromentally friendly CFC-free refrigeration technology to meet the requirements of enviromental protection.

 Using high-quality full-enclosed air-cooled compressor cooling system, low noise

 Full-enclosed air-cooled compressor cooling system with thermal overload protection automatically

 With a power-off protection function, automatically delayed for three minutes

 Using 7 touch display, easy to understand working condition

 Easy to operate, can set the temperature quickly with soft button

 Intelligent PID automatically adjust control function

 Upper and lower temperature alarm can be set

 With over heat alarm system to ensure the safety apparatus

 Inner high-quality stainless steel material

 With external circulating pump, can be established the second constant temperature field outside the bath

 Cold liquid can be cited outside the tank, cooling the experimental container outside the bath

 Using analogue theory , automatic identify the difference between set temperature and the ambient temperature, to confirm whether a single heating or cooling heating work simultaneously to achieve the energy saving

Using DC speed pump, 0-20L / min adjustable flow, head for 5 meters.


Main Technical Parameters

Model

Temperature range(℃)

Temperature

Stability(℃)

Display Resolution(℃)

Tank size (mm3 )

Head

Pump flow

L/min

Tank size

Drainage

SDC-6

-5~100

±0.05

0.1

260*200*140

5

0-20

180*140

DC-1006

-10~100

±0.05

0.1

260*200*140

5

0-20

180*140

DC-2006

-20~100

±0.05

0.1

260*200*140

5

0-20

180*140

DC-3006

-30~100

±0.1

0.1

260*200*140

5

6

180*140

DC-4006

-40~100

±0.1

0.1

260*200*140

5

6

180*140

DC-0510

-5~100

±0.05

0.1

260*200*200

5

6

180*140

DC-1010

-10~100

±0.05

0.1

260*200*200

5

6

180*140

DC-2010

-20~100

±0.05

0.1

260*200*200

5

6

180*140

DC-3010

-30~100

±0.1

0.1

260*200*200

5

6

180*140

DC-4010

-40~100

±0.1

0.1

260*200*200

5

6

180*140

DC-0515

-5~100

±0.05

0.1

300*250*200

5

6

235*160

DC-1015

-10~100

±0.05

0.1

300*250*200

5

6

235*160

DC-2015

-20~100

±0.05

0.1

300*250*200

5

6

235*160

DC-3015

-30~100

±0.1

0.1

300*250*200

5

6

235*160

DC-4015

-40~100

±0.1

0.1

300*250*200

5

6

235*160

DC-1020

-10~100

±0.05

0.1

280*250*280

5

6

235*160

DC-2020

-20~100

±0.05

0.1

280*250*280

5

6

235*160

DC-3020

-30~100

±0.1

0.1

280*250*280

5

6

235*160

DC-0530

-5~100

±0.05

0.1

440*325*200

5

13

310*280

DC-1030

-10~100

±0.05

0.1

440*325*200

5

13

310*280

DC-2030

-20~100

±0.05

0.1

440*325*200

5

13

310*280

DC-3030

-30~100

±0.1

0.1

440*325*200

5

13

310*280

DCW-1015

-10~100

±0.05

0.1

280*250*220

5

6

235*160

DCW-2008

-20~100

±0.05

0.1

280*250*140

5

6

235*16

DCW-3506

-35~100

±0.1

0.1

260*200*140

5

6

180*140

DCW-3510

-35~100

±0.1

0.1

250*200*200

5

6

180*140

DCW-0506

-6~100

±0.05

0.1

260*200*140

5

6

180*140

DCW-4006

-40~100

±0.1

0.1

260*200*140

5

6

180*140

photobank (22)

photobank(4)

photobank (12)

The selection of liquid medium in the cryostat should meet the following principles:


a. When the working temperature is between 5 and 85 ° C, the liquid medium is generally selected from water;

b. When the working temperature is 85 ~ 95 ° C, the liquid medium can be selected with 15% glycerol aqueous solution;

c. When the working temperature is lower than 5 ° C, the liquid medium is generally selected from alcohol or frozen liquid.


3. After the low temperature thermostat cooling switch is turned off, turn the cooling switch on again for 10~20 minutes (depending on the ambient temperature).

4. Low temperature constant temperature tank power supply: 220V50Hz, the power supply should be greater than the total power of the instrument, and the power supply must have a good "grounding" device.


5. The low temperature thermostatic bath should be placed in a dry and ventilated place, and there is no obstacle in the 300mm around the instrument. When the operating temperature of the cryostat is low, care should be taken not to enter the tank to prevent frostbite. After use, all switches are turned off and the power is turned off. The cryostat should be cleaned regularly to keep the work surface and the operation panel clean.


Circulating pump connection:

A. The inner circulation pump is connected, and the water outlet and the return port are connected by a pipe.

B. The external circulation pump is connected to the outer circulation, and the outlet is connected to the inlet of the outer container of the tank, and the outlet is connected to the nozzle of the outer container.

Pipeline description:

Return port                   Outlet                                           Return port       Outlet 

image                                   image

  (Fig. 1.1) Inner loop                                              (Fig. 1.2) Outer loop

                                (Figure 1) Pipeline Description


Internal circulation: Hose with water outlet and return port (Figure 1.1)

External circulation: Connect the water outlet and the return port to the outer container separately to establish a second constant temperature field (Figure 1.2).



Hot Tags: thermostatic digital shaking water bath, China, factory, suppliers, wholesale, customized, buy, cheap, bulk, price list, for sale
Inquiry